Skip to main content
Home
Exista AG
Power Supplies

Sidemenu [EN]

  • Contact
  • Search
  • Terms and conditions
  • Vacancies
  • English
  • German
Product finder
  • Products
    • AC/DC power supplies
    • DC/DC-converter
    • DC/AC inverter
    • Car chargers
    • LED systems
    • LED power supplies
    • DC UPS
    • Battery pack
    • Power Electronics
  • Sectors/Solutions
    • Rail and transport
    • Industry
    • Medicine
    • Household
    • LED lighting technology
  • Services
    • Consultation
    • Development
    • Production
    • Project management
    • Repairs and service
    • Transport and logistics
  • Company
    • About us
    • Downloads
    • Contact
    • Vacancies
Search product name Reset selection

Operating mode

  • dc/ac

Power

  • 51 – 100 W
  • 101 – 150 W
  • 151 – 200 W
  • 201 – 250 W
  • 251 – 350 W
  • 351 – 1200 W
  • 1201 – 2400 W
  • 2401 – 9999 W

Design

  • enclosed
  • 19" rack mountable

Field of application

  • railway
  • industrial

Output voltage

  • 3.3 Vdc
  • 5 Vdc
  • 12 Vdc
  • 15 Vdc
  • 24 Vdc
  • 30 Vdc
  • 48 Vdc
  • 60 Vdc
  • 110 Vac
  • 115 Vac
  • (-) 230 Vac

Numbers of output

  • 1

New products

  • new product

INVC125

power:
100 W
data sheet:
INVC125_Eng.pdf
Kurzbeschrieb:
  • Überlast- und kurzschlussfest
  • Optisches Signal für Überlast
  • Optisches Signal für Betrieb
  • Potentialfei
  • 107*129*170 mm (B*H*T)
Short description:
  • Overload- and permanently short-circuit protected
  • Optical signal power on / PG
  • Optical signal overload / OVL
  • Potential free
  • 107*129*170 mm (W*H*D)

INVT125

power:
100 W
data sheet:
INVT125_Eng.pdf
Kurzbeschrieb:
  • Überlast- und kurzschlussfest
  • Potentialfreier Signalausgang
  • Optisches Signal für Überlast
  • Optisches Signal für Betrieb
  • 243*72*175 mm (B*H*T)
Short description:
  • Overload- and permanently short-circuit protected
  • Voltage free alarm contact
  • Optical signal power on / PG
  • Optical signal overload / OVL
  • 243*72*175 mm (W*H*D)

INVW125

power:
100 W
data sheet:
INVW125_Eng.pdf
Kurzbeschrieb:
  • Überlast- und kurzschlussfest
  • Potentialfreier Signalausgang
  • Optisches Signal für Überlast
  • Optisches Signal für Betrieb
  • 326*74*175 mm (B*H*T)
Short description:
  • Overload- and permanently short-circuit protected
  • Voltage free alarm contact
  • Optical signal power on / PG
  • Optical signal overload / OVL
  • 326*74*175 mm (W*H*D)

INVT250

power:
200 W
data sheet:
INVT250_Eng.pdf
Kurzbeschrieb:
  • Überlast- und kurzschlussfest
  • Potentialfreier Alarmkontakt
  • Optisches Signal für Überlast
  • Optisches Signal für Betrieb
  • 243*72*175 mm (B*H*T)
Short description:
  • Overload- and permanently short-circuit protected
  • Voltage free alarm contact
  • Optical signal power on / PG
  • Optical signal overload / OVL
  • 243*72*175 mm (W*H*D)

INVW250

power:
200 W
data sheet:
INVW250_Eng.pdf
Kurzbeschrieb:
  • Überlast- und kurzschlussfest
  • Potentialfreier Alarmkontakt
  • Optisches Signal für Überlast
  • Optisches Signal für Betrieb
  • 326*74*175 mm (B*H*T)
Short description:
  • Overload- and permanently short-circuit protected
  • Voltage free alarm contact
  • Optical signal power on / PG
  • Optical signal overload / OVL
  • 326*74*175 mm (W*H*D)

NTS-250P

power:
250 W
data sheet:
NTS-250P
Kurzbeschrieb:
  • IEC62368-1
  • True Sine Wave
  • Verpolungsschutz am Eingang
  • Abschaltung bei schwacher Batterie
  • Remote ON/OFF
  • 186*100.5*32 mm (L*B*H)
Short description:
  • IEC62368-1
  • True Sine Wave
  • Reverse polarity protection at the input
  • Battery low shutdown
  • Built-in remote ON-Off control
  • 186*100.5*32 mm (L*W*H)

NTS-300

power:
300 W
data sheet:
NTS-300
Kurzbeschrieb:
  • IEC/ EN62368-1
  • True Sine Wave
  • Verpolungsschutz am Eingang
  • Abschaltung bei schwacher Batterie
  • Remote ON/OFF
  • 210*130*55 mm (L*B*H)
Short description:
  • IEC/ EN62368-1
  • True Sine Wave
  • Reverse polarity protection at the input
  • Battery low shutdown
  • Built-in remote ON-Off control
  • 210*130*55 mm (L*W*H)

INVB500

power:
400 W
data sheet:
INVB500_Eng.pdf
Kurzbeschrieb:
  • Potentialfreier Alarmkontakt
  • Statischer ByPass
  • Wirkungsgrad >88% bei Nennlast
  • 427*133.35*240 mm (B*H*T)
Short description:
  • Voltage free alarm contact
  • Built-in static bypass
  • Efficiency >88% at nominal load
  • 427*133.35*240 mm (W*H*D)

INVP500

power:
400 W
data sheet:
INVP500_Eng.pdf
Kurzbeschrieb:
  • Parallel schaltbar
  • Potentialfreier Alarmkontakt
  • Wirkungsgrad >88% bei Nennlast
  • 427*133.35*240 mm (B*H*T)
Short description:
  • With parallel mode module
  • Voltage free alarm contact
  • Efficiency >88% at nominal load
  • 427*133.35*240 mm (W*H*D)

INVW500

power:
400 W
data sheet:
INVW500_Eng.pdf
Kurzbeschrieb:
  • Potentialfreier Alarmkontakt
  • Optisches Signal für Überlast
  • Optisches Signal für Betrieb
  • Wirkungsgrad >87% bei Nennlast
  • 270*255*115 mm (B*H*T)
Short description:
  • Voltage free alarm contact
  • Optical signal power on / PG
  • Optical signal overload / OVL
  • Efficiency >87% at nominal load
  • 270*255*115 mm (W*H*D)

INVWR500

power:
400 W
data sheet:
INVWR500_Eng.pdf
Kurzbeschrieb:
  • Überlast- und kurzschlussfest
  • Potentialfreier Alarmkontakt
  • Schutzklasse IP54
  • Verriegelbare Industristecker
  • Bahn-Norm EN 50155 konform
  • 270*255*115 mm (B*H*T)
Short description:
  • Overload- and permanently short-circuit protected
  • Voltage free alarm contact
  • IP 54 classification
  • Lockable heavy duty connectors
  • According to rail norm EN50155
  • 270*255*115 mm (W*H*D)

NTS-400P

power:
400 W
data sheet:
NTS-400P
Kurzbeschrieb:
  • IEC62368-1
  • True Sine Wave
  • Verpolungsschutz am Eingang
  • Abschaltung bei schwacher Batterie
  • Remote ON/OFF
  • 186*100.5*32 mm (L*B*H)
Short description:
  • IEC62368-1
  • True Sine Wave
  • Reverse polarity protection at the input
  • Battery low shutdown
  • Built-in remote ON-Off control
  • 186*100.5*32 mm (L*W*H)

NTS-450

power:
450 W
data sheet:
NTS-450
Kurzbeschrieb:
  • IEC/ EN62368-1
  • True Sine Wave
  • Verpolungsschutz am Eingang
  • Abschaltung bei schwacher Batterie
  • Remote ON/OFF
  • 210*130*55 mm (L*B*H)
Short description:
  • IEC/ EN62368-1
  • True Sine Wave
  • Reverse polarity protection at the input
  • Battery low shutdown
  • Built-in remote ON-Off control
  • 210*130*55 mm (L*W*H)

NTS-750

power:
750 W
data sheet:
NTS-750
Kurzbeschrieb:
  • IEC/ EN62368-1
  • True Sine Wave
  • Verpolungsschutz am Eingang
  • Abschaltung bei schwacher Batterie
  • Remote ON/OFF
  • 270*158*67 mm (L*B*H)
Short description:
  • IEC/ EN62368-1
  • True Sine Wave
  • Reverse polarity protection at the input
  • Battery low shutdown
  • Built-in remote ON-Off control
  • 270*158*67 mm (L*W*H)

INVB1000

power:
800 W
data sheet:
INVB1000_Eng.pdf
Kurzbeschrieb:
  • Potentialfreier Alarmkontakt
  • Statischer ByPass
  • Wirkungsgrad >88% bei Nennlast
  • 427*133.35*240 mm (B*H*T)
Short description:
  • Voltage free alarm contact
  • Built-in static bypass
  • Efficiency >88% at nominal load
  • 427*133.35*240 mm (W*H*D)

INVP1000

power:
800 W
data sheet:
INVP1000_Eng.pdf
Kurzbeschrieb:
  • Parallel schaltbar
  • Potentialfreier Alarmkontakt
  • Wirkungsgrad >88% bei Nennlast
  • 427*133.35*240 mm (B*H*T)
Short description:
  • With parallel mode module
  • Voltage free alarm contact
  • Efficiency >88% at nominal load
  • 427*133.35*240 mm (W*H*D)

NTS-1200

power:
1200 W
data sheet:
NTS-1200
Kurzbeschrieb:
  • IEC/ EN62368-1
  • True Sine Wave
  • Verpolungsschutz am Eingang
  • Abschaltung bei schwacher Batterie
  • Remote ON/OFF
  • 333*184*70 mm (L*B*H)
Short description:
  • IEC/ EN62368-1
  • True Sine Wave
  • Reverse polarity protection at the input
  • Battery low shutdown
  • Built-in remote ON-Off control
  • 333*184*70 mm (L*W*H)

TS-1500

Im Abkündigungsprozess. Bitte Verkauf kontaktieren
In the process of discontinuation. Please contact sale
power:
1500 W
data sheet:
TS-1500
Kurzbeschrieb:
  • IEC62368-1
  • Verpolungsschutz am Eingang
  • Abschaltung bei schwacher Batterie
  • Ein- Aus-Schalter
  • Kurzzeitig bis 200% Leistung
  • 420*220*88 mm (L*B*H)
Short description:
  • IEC62368-1
  • Reverse polarity protection at the input
  • Battery low shutdown
  • Power ON-OFF switch
  • High surge power up to 200%
  • 420*220*88 mm (L*W*H)

INVB2000

power:
1600 W
data sheet:
INVB2000_Eng.pdf
Kurzbeschrieb:
  • Potentialfreier Alarmkontakt
  • Statischer ByPass
  • Wirkungsgrad >88% bei Nennlast
  • 427*133.35*360 mm (B*H*T)
Short description:
  • Voltage free alarm contact
  • Built-in static bypass
  • Efficiency >88% at nominal load
  • 427*133.35*360 mm (W*H*D)

INVBL2000

power:
1600 W
data sheet:
INVBL2000_Eng.pdf
Kurzbeschrieb:
  • Potentialfreier Alarmkontakt
  • Statischer ByPass
  • Wirkungsgrad >88% bei Nennlast
  • PC Schnittstelle für Datenabruf
  • 427*133.35*360 mm (B*H*T)
Short description:
  • Voltage free alarm contact
  • Built-in static bypass
  • Efficiency >88% at nominal load
  • PC interface for data recall
  • 427*133.35*360 mm (W*H*D)

INVP2000

power:
1600 W
data sheet:
INVP2000_Eng.pdf
Kurzbeschrieb:
  • Parallel schaltbar
  • Potentialfreier Alarmkontakt
  • Wirkungsgrad >88% bei Nennlast
  • 427*133.35*360 mm (B*H*T)
Short description:
  • With parallel mode module
  • Voltage free alarm contact
  • Efficiency >88% at nominal load
  • 427*133.35*360 mm (W*H*D)

LAV2000

power:
1600 W
data sheet:
LAV2000_Eng.pdf
Kurzbeschrieb:
  • Bis zu 12 Geräte parallel schaltbar
  • Wirkungsgrad >88% bei Nennlast
  • Geringe Ausgangsimpedanz
  • 427*133.35*360 mm (B*H*T)
Short description:
  • Up to 12 parallel inverter per external controller
  • Efficiency >88% at nominal load
  • Low output impedance
  • 427*133.35*360 mm (W*H*D)

TS-3000

Im Abkündigungsprozess. Bitte Verkauf kontaktieren
In the process of discontinuation. Please contact sale
power:
3000 W
data sheet:
TS-3000
Kurzbeschrieb:
  • IEC62368-1
  • Verpolungsschutz am Eingang
  • Abschaltung bei schwacher Batterie
  • Ein- Aus-Schalter
  • Kurzzeitig bis 200% Leistung
  • 466.8*283.5*100 mm (L*B*H)
Short description:
  • IEC62368-1
  • Reverse polarity protection at the input
  • Battery low shutdown
  • Power ON-OFF switch
  • High surge power up to 200%
  • 466.8*283.5*100 mm (L*W*H)

INVBL4000

power:
3200 W
data sheet:
INVBL4000_Eng.pdf
Kurzbeschrieb:
  • Potentialfreier Alarmkontakt
  • Statischer ByPass
  • Wirkungsgrad >88% bei Nennlast
  • PC Schnittstelle für Datenabruf
  • 427*133.5*360 mm (B*H*T)
Short description:
  • Voltage free alarm contact
  • Built-in static bypass
  • Efficiency >88% at nominal load
  • PC interface for data recall
  • 427*133.5*360 mm (W*H*D)

INVPL4000

power:
3200 W
data sheet:
INVPL4000_Eng.pdf
Kurzbeschrieb:
  • Parallel schaltbar
  • Potentialfreier Alarmkontakt
  • Wirkungsgrad >88% bei Nennlast
  • PC Schnittstelle für Datenabruf
  • 427*133.35*360 mm (B*H*T)
Short description:
  • With parallel mode module
  • Voltage free alarm contact
  • Efficiency >88% at nominal load
  • PC interface for data recall
  • 427*133.35*360 mm (W*H*D)

LAV4000

power:
3200 W
data sheet:
LAV4000_Eng.pdf
Kurzbeschrieb:
  • Bis zu 12 Geräte parallel schaltbar
  • Wirkungsgrad >88% bei Nennlast
  • Geringe Ausgangsimpedanz
  • 427*133.35*360 mm (B*H*T)
Short description:
  • Up to 12 parallel inverter per external controller
  • Efficiency >88% at nominal load
  • Low output impedance
  • 427*133.35*360 mm (W*H*D)
Exista AG Mettlenbachstrasse 23 CH-8617 Mönchaltorf