MSP-1000

  • Leerlaufleistung <0.75W
  • Aktives PFC
  • Remote ON/OFF
  • Remote Sense
  • Weiter Temperaturbereich
  • 5 Jahre Herstellergarantie
  • 218*105*63.5 mm (L*B*H)
  • No load power consumption <0.75W
  • Built-in active PFC
  • Built-in remote ON/OFF
  • Built-in remote sense
  • Wide temperature range
  • 5 years manufacturer warranty
  • 218*105*63.5 mm (L*W*H)
standards

ANSI/AAMI ES60601-1, IEC60601-1 ; CAN/CSA-C22.2 No.60601-1:14-Edition 3 approved; Design refer to BS EN/EN60601-1, BS EN/EN62368-1

Technische Daten
Technical data
field of application medical
design enclosed
operating mode ac/dc
power 1000 W
input voltage 1 90 Vac – 264 Vac
input voltage 2 127 Vdc – 370 Vdc
output voltage 12 Vdc | 15 Vdc | 24 Vdc | 48 Vdc
operating temperature -40 °C ... +70 °C
numbers of output 1
manufacturer Mean Well