Skip to main content
Home
Exista AG
Power Supplies

Sidemenu [EN]

  • Contact
  • Search
  • Terms and conditions
  • Vacancies
  • English
  • German
Product finder
  • Products
    • AC/DC power supplies
    • DC/DC-converter
    • DC/AC inverter
    • Car chargers
    • LED systems
    • LED power supplies
    • DC UPS
    • Battery pack
    • Power Electronics
  • Sectors/Solutions
    • Rail and transport
    • Industry
    • Medicine
    • Household
    • LED lighting technology
  • Services
    • Consultation
    • Development
    • Production
    • Project management
    • Repairs and service
    • Transport and logistics
  • Company
    • About us
    • Downloads
    • Contact
    • Vacancies
Search product name Reset selection

Operating mode

  • dc/ac

Design

  • enclosed
  • (-) DIN-rail
  • (-) 19" rack mountable

Manufacturer

  • Mean Well
  • Power Innovation

Field of application

  • industrial

Numbers of output

  • 1

Accessories

  • (-) accessories

DBUF20-24

Puffermodul
Buffermodule
data sheet:
DBUF20-24
Kurzbeschrieb:
  • LED Anzeige für Signalstatus
  • Unterstützt Parallelschaltung zur Verlängerung der Pufferungszeit
Short description:
  • LED indicator for signal status
  • Supports paralle connection to extend buffering time

DBUF40-24

Puffermodul
Buffermodule
data sheet:
DBUF40-24
Kurzbeschrieb:
  • LED Anzeige für Signalstatus
  • Unterstützt Parallelschaltung zur Verlängerung der Pufferungszeit
Short description:
  • LED indicator for signal status
  • Supports paralle connection to extend buffering time

ICL-16R/ ICL-16L

Einschaltstrombegrenzer
Inrush current limiter
data sheet:
ICL-16R_16L
Kurzbeschrieb:
  • 23A Einschaltstrombegrenzung/ 16A dauernd
  • Interner Temperaturschutz
  • Integriertes Überbrückungsrelais
Short description:
  • 23A inrush limiting current, 16A continuous
  • Internal therma protection
  • integrated bypass relay

LAVBYP120

Zubehör zu LAV
Equipment for LAV
data sheet:
LAVBYP120_Eng.pdf
Kurzbeschrieb:
  • Elektronischer ByPass
  • Nennstrom 120 A
  • Übertemperatur- und Lüfterfehlerkennung
  • Statusmeldung an Kontroller
  • Redundant zum Kontroller
  • 427*133.35*201 mm (B*H*T)
Short description:
  • Electronic bypass
  • Rated current 120A
  • Overtemperature and fan failure detection
  • State report to controller
  • Redundant to controller
  • 427*133.35*201 mm (W*H*D)

LAVBYP200

Zubehör zu LAV
Equipment for LAV
data sheet:
LAVBYP200_Eng.pdf
Kurzbeschrieb:
  • Elektronischer ByPass
  • Nennstrom 200 A
  • Übertemperatur- und Lüfterfehlerkennung
  • Statusmedlung an Kontroller
  • Redundant zum Kontroller
  • 427*177.8*360 mm (B*H*T)
Short description:
  • Electronic bypass
  • Rated current 120A
  • Overtemperature and fan failure detection
  • State report to controller
  • Redundant to controller
  • 427*177.8*360 mm (W*H*D)

LAVCON

Zubehör zu LAV
Equipment for LAV
data sheet:
LAVCON_Eng.pdf
Kurzbeschrieb:
  • Kontrolleinheit für LAV-Geräte
  • Steuerung bis zu 12 Inverter
  • Automatische Erkennung der Ausgangsleistung
  • Auto-Alarm über optionales Modem
  • Batterie- und Netzspannungsüberwachung
  • 427*88.9*201 mm (B*H*T)
Short description:
  • Interface converter for LAV-units
  • Up to 12 inverters connectable
  • Mixed inverter output power detection
  • Alarm report auto-sent via optional modem
  • Monitoring of DC input and mains voltage
  • 427*88.9*201 mm (W*H*D)
Exista AG Mettlenbachstrasse 23 CH-8617 Mönchaltorf
Phone +41 - 43 204 01 01
Email sales@exista.ch
 

Footermenu [EN]

  • Imprint
  • Privacy